Skip to content
Clear product details Fitment guidance Contact support
DriveSelect Compare the options that matter.

CARLIN 5020002S 120V Oil Primary Control nterrupted Duty Ignition Recycle on Flame Failure | Options and Comparison Guide

$99.36

7 ratingsSource: Amazon
SKU: E-B00OM05GBW Category:

Comparison view: Compare CARLIN 5020002S 120V Oil Primary Control nterrupted Duty Ignition Recycle on Flame Failure with other Control Units options using this source-backed discriminator: CARLIN 50200-02(S) OIL PRIMARY CONTROL Features & Benefits Interrupted Duty Ignition Recycle on Flame Failure Serviceman Reset Protection ( Latch-up after three consecutive lockouts) Diagnostic LED’s 15 Second Trial for Ignition (TFI) Other Timings Available 1.3 Second Flame Failure response time (FFRT) Alarm Contacts Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology Power Input (From Limit Ci.

Use this second point to evaluate the tradeoff: Category: Replacement Parts / Ignition Parts / Control Units. Use a comparison lens: material, dimensions, compatibility, package scope, and upgrade tradeoffs.

Before you order
  • Confirm the part number, position, dimensions, and connector details shown on this page.
  • Compare the listing with the part currently installed on your vehicle.

Description

Comparison points and tradeoffs

When comparing CARLIN 5020002S 120V Oil Primary Control nterrupted Duty Ignition Recycle on Flame Failure with other Control Units options, use this source-backed detail as the primary discriminator: CARLIN 50200-02(S) OIL PRIMARY CONTROL Features & Benefits Interrupted Duty Ignition Recycle on Flame Failure Serviceman Reset Protection ( Latch-up after three consecutive lockouts) Diagnostic LED’s 15 Second Trial for Ignition (TFI) Other Timings Available 1.3 Second Flame Failure response time (FFRT) Alarm Contacts Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology Power Input (From Limit Ci.

Use this second fact to evaluate the tradeoff: Category: Replacement Parts / Ignition Parts / Control Units. A third point to compare across alternatives is: Alarm Contacts Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology.

Alternative-selection boundary

Choose an alternative when its stated identifiers, application, package, or specifications better match the requirement; no unverified competitor claim is introduced here.

Complete source-backed product details

CARLIN 50200-02(S) OIL PRIMARY CONTROL Features & Benefits Interrupted Duty Ignition Recycle on Flame Failure Serviceman Reset Protection ( Latch-up after three consecutive lockouts) Diagnostic LED’s 15 Second Trial for Ignition (TFI) Other Timings Available 1.3 Second Flame Failure response time (FFRT) Alarm Contacts Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology Power Input (From Limit Circuit) 120 vac, 60 Hz, 9 VA Motor Load 10 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA Alarm Contacts 24 V, AC/DC, 2 A Operating Temperature Limits + 32°F to + 140°F Storage Temperature Limits -40°F to +185°F Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R

Source product highlights

  • CARLIN 5020002S OIL PRIMARY CONTROL
  • 15 Second Trial for Ignition (TFI)
  • 1.3 Second Flame Failure response time (FFRT)
  • Alarm Contacts Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology
  • Power Input (From Limit Circuit) 120 vac, 60 Hz, 9 VA Motor Load 10 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA Alarm Contacts 24 V, AC/DC, 2 A

Product facts

Specifications

Canonical product
MP-US-B00OM05GBW
Source product ID
B00OM05GBW
Category
Replacement Parts / Ignition Parts / Control Units
Available images
1

No structured vehicle fitment data is available. Compare the listing with the vehicle and existing part before ordering.

Selection, alternatives, tradeoffs, upgrades, and direct replacements

Buying guidance

Quick decision

Use the supplied facts to compare this control units with direct replacements and nearby alternatives.

Choose this if

  • The listed specifications and referenced numbers match the part you need.
  • The package contents cover the repair without missing required components.

Consider another option if

  • Your vehicle, connector, side, dimensions, or part number do not match the listing.
  • You need a different package quantity, material, or variation.

Before you buy

  • Compare the listing title, photos, package contents, and specifications with the part being replaced.
  • Confirm vehicle compatibility and installation requirements before ordering.

Customer feedback

Ratings and written reviews

4.3 / 5 7 source ratings

Source: Amazon. Imported marketplace feedback is shown for product research and is not a review of a purchase made on this website.

3 written reviews
5 stars 1
4 stars 1
3 stars 0
2 stars 0
1 star 1

3 reviews for CARLIN 5020002S 120V Oil Primary Control nterrupted Duty Ignition Recycle on Flame Failure | Options and Comparison Guide

  1. Imported from AmazonSource context: Verified Purchase

    Dave klein

    Good product

  2. Imported from AmazonSource context: Verified Purchase

    jim magenheimer

    Worked as expected

  3. Imported from AmazonSource context: out the box...BAD...thankfully i bought 2 at one time...thank you CHINA

    Jay l.

    out the box…BAD…thankfully i bought 2 at one time…thank you CHINA

Add a review

Your email address will not be published. Required fields are marked *